Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Indian J Ophthalmol ; 2019 Dec; 67(12): 2078-2080
Article | IMSEAR | ID: sea-197677

ABSTRACT

Ocular amylodosis, although a rare entity, is known to affect the conjunctiva, extraocular muscles, orbit, lacrimal gland, and skin around the eyes. Intraocular deposition of amyloid mainly confines to the vitreous and cornea. In this report, we describe two cases of intraocular amyloidosis presenting as multiple iris and anterior chamber cysts. Histopathological examination with special stain like Congo Red and Transmission Electron Microscopy confirmed the diagnosis of amyloidosis. Systemic investigations ruled out systemic association confirming the diagnosis of primary ocular amyloidosis.

2.
Indian J Ophthalmol ; 2018 Nov; 66(11): 1600-1607
Article | IMSEAR | ID: sea-196960

ABSTRACT

Purpose: To describe the outcomes of a patient-specific implant (PSI), fabricated using a three-dimensional (3D) printed orbital template and placed in the basin of the inferior orbital fissure to correct inferotemporally migrated spherical orbital implant. Methods: This is a single-center, prospective, consecutive, interventional, case series of six patients, with non-porous, spherical, orbital implant migration that underwent implant recentration surgically with a novel technique. Migration was subclassified either as decentration that did not affect the prosthetic retention or as displacement that affected the prosthetic retention in the eye socket. Only implant displacements were treated. The primary outcome measure was centration of the implant clinically and radiologically, with ability to retain the prosthesis. Results: At a mean follow-up of 21 months, all six orbital spherical implants remained centered. There were no cases of extrusion, exposure, or migration of either implants. There were no cases of PSI displacement. Additional procedures to optimize the aesthetic outcome of the customized ocular prosthesis (COP) required were simultaneous fornix formation suture in three patients, subsequent fornix formation with mucus membrane graft in two patients, and levator resection and sulcus hyaluronic acid gel injection in one patient each. The mean PSI implant weight was 2.66 ± 0.53 g. The mean COP weight was 2.2 ± 0.88 g postoperatively. The median patient satisfaction with the procedure was 9 on 10. Conclusion: A 3D printing-assisted PSI placed in the basin of the inferior orbital fissure allows recentration of the migrated implant over a follow-up of 21 months without complications.

SELECTION OF CITATIONS
SEARCH DETAIL